BCG SK KORROSION Corrosion Protection for Heating Systems and Pipes
BCG SK KORROSION Corrosion Protection for Heating Systems and Pipes
- Brand: BACOGA
- Product Code: BCG SK KORROSION
- Availability: In Stock
- 150.06€
135.05€
- Ex Tax: 109.80€
Description:
BACOGA BCG® SK Korrosion is designed to protect heating systems with pipes and components made of steel, aluminum, and copper against corrosion. It also safeguards underfloor heating systems with plastic pipes by preventing oxygen diffusion through the formation of a diffusion-tight protective film on the inside of the pipes. SK Korrosion effectively prevents limescale deposits on pipe walls, ensuring the formation of an optimal corrosion protection film.
BCG SK Korrosion keeps control units and pipelines in the system free of sediments, offering protection for both new and existing heating systems. No special tools are required to fill BCG SK Korrosion anti-corrosion liquid into a heating system.
BACOGA BCG SK Korrosion User Instructions:
Note: Rinse heavily soiled systems thoroughly beforehand and clean if necessary with SR Reiniger.
- Empty approximately 20 liters of system water from the system.
- Close the filling/draining tap (1).
- Drain the filling hose of water.
- Fill the SK Korrosion into the hose using a funnel.
- Connect the hose to the tap (2).
- Open the filling/draining tap (1).
- Open the tap (2). SK Korrosion is now pressed into the heating circuit.
- Close the tap (2) and the fill/drain tap.
- Disconnect the hose from the tap (2) and empty it.
- Repeat the process until the required amount of SK Korrosion fills the system.
- Fill the heating system to operating pressure.
- Fully open all heating and mixing valves.
- Set the heating system to operating temperature.
- Vent the system.
- SK Korrosion must now remain in the system.
- Check the dosage of SK Korrosion approximately 1 week after filling with BCG Test. The molybdate content should be between 250 and 400 mg/l Mo.
- As BCG SK Korrosion remover dissolves and loosens existing deposits, thoroughly rinse the heating system after approximately 1 to 3 months. Then refill the system with SK Korrosion as described above, and measure the concentration again. Corrosion protection is lost if SK Korrosion is dosed insufficiently.
Note: It is recommended to consult an authorized plumber before using the product.
Safety Data for BCG SK Korrosion:
In case of contact with eyes, rinse immediately with water and consult a physician. In case of skin contact, wash immediately with plenty of water. Wear suitable protective gloves and eye/face protection when working. The usual precautions when handling chemicals must be observed! Keep out of reach of children!
Disposal: See safety data sheet.
Composition: Molybdate-containing product with added CU inhibitors.
Mixing Ratio: 1 liter of SK Korrosion per 200 liters of system water.
Shelf Life/Storage: Unopened 5 years from the date of manufacture. Protect from frost.
Note: There must be no additives in the heating system (frost and corrosion protection). Filters, sieves, and dirt traps must be removed or a bypass must be established.